• Fully Indigenous
  • Sensor With 3 Year Warranty
  • VLSI Technology
  • Customised Sensor Technology
  • No Charger
Technical Specifications

Parameters
Range
Accuracy
Resolution
O2
0 TO 21%
±2% of Reading
0.1%
CO
0 TO 4000PPM
± 2% of Reading
1 ppm
Type CR-AL / RTD
0TO 600*C
±1% of Reading for K type ± 0.75% of Reading for RTD ± 2% of Reading
1°C
CO2 Derived
0 TO 21%
± 2% of Reading
0.1%
Combustion Efficiency(Derived)
0 TO 100%
1% between
70% TO 95%
0.1%

Power
  • 9 V Alkaline cells. Easy to replace, Maintenance free, Charger option also available
Battery Capacity
  • Battery can take 2 Hrs continuous reading
Probe
  • Standard probe suitable for 0 TO 600 °C temperature / 350 mm rigid section and 2 mtr. neoprene tubing
Display
  • 8 Character dot matrix LCD Scrolling display
Switch
  • Membrane Polycarbonate Keyboard with tactile keys
Size
  • 150mm X 80mm X 30mm
Pump
  • Can suck stack gas up to 400 mm wc
Calibration
  • Provision for automatic and manual calibration (with known gas)
Data Storage & Interface
  • It comes with RS 232, interface cable software floppy. It can Store 250 sets of readings.
Important Features
  • Instrument can operate on fuels ranging from Kerosene, LCD, HSD, LSHS, F.O, NATURAL GAS, COAL etc. Customer can feed the program for non-standard fuel codes.

  • Calorific value is based on locally available fuels.

  • CO2 Excess Air and combustion efficiency reading are calculated as per BS 845

  • User friendly interface with the operator by means of elaborate message.

  • Pocket size, Lightweight easy to carry

  • No charger required. Works on 9V Alkaline Cell
  • Low cost & fully indigenous
Application
  • Textiles

  • Pharmaceuticals

  • Energy Audits & Environmental Consultants

  • Refineries & Petrochemicals

  • Breweries

  • Chemicals
  • Other Industries
 

  © 2001 Acegas All Rights Reserved